MIPEG 2000 Operator`s Display has
the following display features:
Four LCD displays, 15 mm high, which will
show:
- Actual hook load
- Hook operating radius
- Sea state or lifting condition
- Safe Working Load (SWL)
When the green "aux" pushbutton is depressed,
time & date, falls (parts of line) and cor % are displayed. The LCD`s and the
display facia are back-lit for night operation. A large analogue needle
displayed on top of a green/yellow and red scale is used to achieve a “corner of
the eye” indication of the % of SWL.
The display is equipped with an amber pre-warning
light and a red alarm light together with a system buzzer, to alert the
operator. All lights, both for back-lightning or alarm levels are LED`s for long
service life.
The unit is sealed to comply to IP65 (dust tight
and water jets). The display can be offered for zone 1 (Class 1
Div 1) operation certified II 2 G EEx ia IIB T4 according to
ATEX , Directive 94/9/EC.
The outside overall box dimensions are H x W x D;
198 x 224 x 60 (mm), the material is copper free aluminium
(weight approx. 3 kg) and the unit is anodised and epoxy coated
black.
The display is mounted on a L-shaped tube with
brackets which allows the display to be tilted in all angles for
optimum viewing angle. The display should be mounted in the
lower section of the front corner of the crane cab to allow the
crane operator to have the display in the corner of the eye,
while maintaining full attention to the lifting operation.
Note that a connector mounted in the bottom of the
display is used for connections to a Lap-Top computer for
calibration and fault finding checks. This is optional in a
Mipeg 2000 Non-Recording system and will also be the point of
retrieving stored crane operation records in a Recording
version. This is a standard RS232C connection only used for test
and maintenance purposes.